Mains analyser with alarms
• Alarms, programmable in value and delay
• Graphical and numerical display in real time. Measurements: RMS, Peak, AC and DC
• Oscilloscope-event logger in waveform with pre-trigger (600-event built-in memory)
• Graphical history of THD–HD–VAr averaged at 5-minute intervals, for analysis of harmonic compensation and reactive power, with built-in 14-month memory
• 7-channel oscilloscope with autoscale and instantaneous value measurement cursor
• 64-harmonic spectrum with distortion range in % and value V – A, + THD
• 64-harmonic spectrum with calculations of power, power factor, distortion range in % and value V – A, + THD
• Measurement and alarm of THD from harmonic 2 – 63, programmable by harmonic and harmonics range
• Dynamic measurements of 1600 electrical parameters + temperature and humidity
• 10 relays with alarms, timers, schedule programmer, control of 10 inputs and manual control
• Graphical history (months, days, hours and minutes) of energy, costs and emissions with built-in 3-year memory
• Programming, control and monitoring in real time via Internet / Intranet
+ Administration and control software via Internet / Intranet
• Safeline Web Service for dedicated server
• Data Watch Pro software for PC
• Web applications hosted in server (extensions)
Analyser (standard transformer)
Analyser (Rogowski flexible probe)
Mini analyser (standard transformer)
Mains analyser, programmable and with log
WebServer via Internet / Intranet and Modbus TCP/IP
Graphic and numeric display in real time
6-channel oscilloscope with autoscale, self-refreshing and instantaneous value measurement cursor
Graphic history (months, days, hours and minutes) of energy, costs and emissions (3-year memory)
Administration software: Data Watch Pro and Applications Web (extensions)
Programming, control and monitoring in real time via Internet / Intranet
Mains analysers, multi-line 6 lines or sectors with 6 remote control relays
WebServer via Internet / Intranet and Modbus TCP/IP
Graphic and numeric display in real time. Medidas RMS
7-channel oscilloscope with autoscale, self-refreshing and instantaneous value measurement cursor
Graphic history (months, days, hours and 15-minute intervals) of energy, costs and emissions (2-year memory)
6 remote relays via Internet / Intranet
Programming, control and monitoring in real time via Internet / Intranet
Mains analysers, multi-line 6 lines or sectors
WebServer via Internet / Intranet and Modbus TCP/IP
Graphic and numeric display in real time. Medidas RMS
7-channel oscilloscope with autoscale, self-refreshing and instantaneous value measurement cursor
Graphic history (months, days, hours and 15-minute intervals) of energy, costs and emissions (2-year memory)
Programming, control and monitoring in real time via Internet / Intranet